A hands-on example for setting up and running a molecular dynamics run Tutorial.

vibes supports running molecular dynamics simulations via ASE in NVE, NVT, and NPT ensembles. A minimal md.in for running 1000 steps of Velocity Verlet dynamics with a Lennard Jones calculator would be

[files]
geometry:                      geometry.in

[calculator]
name:                          lj

[calculator.parameters]
sigma:                         3.4

[md]
driver:                        VelocityVerlet
timestep:                      1
maxsteps:                      1000
Click: Default values for the complete list of supported keywords

NVE dynamics using Velocity Verlet propagation (vibes template md)

[md]
driver:                        VelocityVerlet
timestep:                      1
maxsteps:                      1000
compute_stresses:              False
workdir:                       md

[md.kwargs]
logfile:                       md.log
NVT ensemble using a Langevin thermostat (vibes template md --nvt):
[md]
driver:                        Langevin
timestep:                      1
maxsteps:                      1000
compute_stresses:              False
workdir:                       md

[md.kwargs]
temperature:                   300
friction:                      0.02
logfile:                       md.log
NPT ensemble using a Berendsen thermostat and barostat (vibes template md --npt):
[md]
driver:                        NPTBerendsen
timestep:                      1
maxsteps:                      1000
compute_stresses:              False
workdir:                       md

[md.kwargs]
temperature:                   300
taut:                          500.0
taup:                          1000.0
pressure:                      1.01325
compressibility:               4.57e-05
logfile:                       md.log
inhomogeneous:                 False

Sections#

[md]#

driver#

str: The MD algorithm. Either VelocityVerlet (NVE ensemble), Langevin (NVT ensemble), or NPTBerendsen (NPT ensemble).

timestep#

float: the integration timestep in fs.

maxsteps#

int: the number of timesteps to perform.

compute_stresses#

bool/int: specify whether to compute stress during the MD simulation (more costly in ab initio MD).

workdir#

str: the working directory for the MD simulation.

[md.kwargs]#

These are keyword arguments that go straight to the ASE class implementing the MD algorithm, e.g.,

cls = Langevin

md = cls(**settings.md.kwargs)

The keywords are documented in ASE:

For NPTBerendsen, we add the inhomogeneous keyword, which decides if the Inhomogeneous_NPTBerendsen driver is used instead of NPTBerendsen. With Inhomogeneous_NPTBerendsen, the basis vectors are scaled independently, i.e. the size of the unit cell can change in three directions, but the angles remain constant. By default, inhomogeneous=False.

Warning

In ASE, the temperature is usually given as an energy in {\rm eV}. In FHI-vibes, we use Kelvin consistently. temperature: 300 thus corresponds to setting the thermostat to 300\,{\rm K}.